Mettler Toledo Ind 236 User Manual

In food retail, METTLER TOLEDO's offering for the management of fresh food ranges from receiving and prepackaging, to in-store solutions for self-service departments, deli counters, and checkout termi. View online Operation & user’s manual for Mettler Toledo IND570 Scales or simply click Download button to examine the Mettler Toledo IND570 guidelines offline on your desktop or laptop computer. Requirements are unique for every industrial scale so performance must be tested and certified. Our calibration services and certificates document accuracy to ensure production. Accordance with the instruction manual, may cause harmful interference to radio communications. METTLER TOLEDO IND231/IND236 Terminal User's Guide 1 Contents 1. User manual 22015307A 05/08 IND439check / IND439xx check / BBA439check 1.5 Description 1.5.1 Weighing terminals IND439check and IND439xx check METTLER TOLEDO weighing platforms can be connected without problems to the weighing terminals. The weighing terminals are available in two different basic versions: for connecting. Mettler toledo ind 246 terminal technical manual Get Read & Download Ebook mettler toledo ind 246 terminal technical manual as PDF for free at The Biggest ebook library in the world. Get mettler toledo ind 246 terminal technical manual PDF file for free on our ebook library PDF File: mettler toledo ind 246 terminal technical manual.

Notice:This product is restricted to logged in users with appropriate permissions /android-81-oreo-user-manual-pdf.html.

The IND231 and IND236 terminals provide rugged, operator-friendly operation in basic weighing, over/under checkweighing, animal weighing and simple counting applications. The terminals feature a large backlit graphic LCD display, an operator-friendly keypad layout, and multiple connectivity options. Application specific print templates, including date and time information, provide a record of the transaction or integration into PC based software applications. A high efficiency battery option provides long battery life for use in mobile weighing applications. These capabilities make the versatile IND231 and IND236 general purpose transaction weighing terminals suitable for a variety of applications.

Description

Mettler toledo ind 221 calibration manual

Specifications – IND231 and IND236 Terminals

TerminalIND231IND236
Dimensions (WxHxD)220 x 150 x 102mm / 8.66 x 5.90 x 4.02 (inch)220 x 150 x 93.3mm / 8.66 x 5.90 x 3.67 (inch)
ConstructionPlasticStainless Steel
MountingMounting to wall, desk or column via included adjustable angle mounting bracket
PowerAC: 85-264VAC; 50Hz-60Hz
Six”AA”size battery or Ni-MH rechargeable batteryNi-MH rechargeable battery
Operating Environment-10ºC to +40ºC (14ºF to 104ºF), 10% to 95% relative humidity, non-condensing
ProtectionIP54IP66/IP67
Display40mm height weight display, seven digits seven segment LCD with white backlight
Scale Interfaceone analog scale
Load CellUp to 4 350ohm load cells, 5V excitation
Units of Measureg, kg, lb, oz
KeypadSeven function keys: Zero, Tare, Clear, On/Off, Print, F1 & F2 (definable)
Communication OptionsStandard: COM1 RS232
Option: COM2 isolated RS232/RS422/RS485 COM2 USB device for connection to PC COM2 2 input/ 4 output Discrete I/O
ApplicationBasic weighing, X10, Date & Time, Animal weighing, Counting with APW enhancement, Over/Under checkweighing with 10 records database, Accumulation, Remote display
ApprovalsClass III: OIML6000e, NTEP10,000d, CMC6000e, CE, cULus
Accessoriesdesk bracket; terminal protection cover
TerminalIND231IND236
Dimensions (WxHxD)220 x 150 x 102mm / 8.66 x 5.90 x 4.02 (inch)220 x 150 x 93.3mm / 8.66 x 5.90 x 3.67 (inch)
ConstructionPlasticStainless Steel
MountingMounting to wall, desk or column via included adjustable angle mounting bracket
PowerAC: 85-264VAC; 50Hz-60Hz
Six”AA”size battery or Ni-MH rechargeable batteryNi-MH rechargeable battery
Operating Environment-10ºC to 40ºC (14ºF to 104ºF), 10% to 95% relative humidity, non-condensing
ProtectionIP54IP66/IP67
Display40mm height weight display, seven digits seven segment LCD with white backlight
Scale Interfaceone analog scale
Load CellUp to 4 350ohm load cells, 5V excitation
Units of Measureg, kg, lb, oz
KeypadSeven function keys: Zero, Tare, Clear, On/Off, Print, F1 & F2 (definable)
Communication OptionsStandard: COM1 RS232
Option: COM2 isolated RS232/RS422/RS485 COM2 USB device for connection to PC COM2 2 input/ 4 output Discrete I/O
ApplicationBasic weighing, X10, Date & Time, Animal weighing, Counting with APW enhancement, Over/Under checkweighing with 10 records database, Accumulation, Remote display
ApprovalsClass III: OIML6000e, NTEP10,000d, CMC6000e, CE, cULus
Accessoriesdesk bracket; terminal protection cover

Specifications

Mettler Toledo Ind 221 Calibration Manual

236

Mettler Toledo Ind 236 Manual

Housing

Plastic IP54, Stainless Steel IP66/67

Battery

No Battery, AA Dry battery cell (not included), Ni-MH rechargable

Interface

RS232, RS232 RS232/422/485, RS232 USB Device, RS232 digital I/O

Cursive fonts download for android. Jan 21, 2019  Download Cursive Fonts Free apk 9.0 for Android. Cursive Fonts Free is a fonts to install in your phone device.