Hid Iclass Se R10 User Manual
Iclass se cp1000 encoder user guide. Read online or download PDF. HID iCLASS SE Encoder User Guide User Manual Manuals Directory ManualsDir.com - online owner manuals. View and Download HID ICLASS SE CP1000 quick start manual online. Desktop Encoder. ICLASS SE CP1000 Media Converter pdf manual download.
Page 4: Installation guide 4, Attention, Terminal reader pigtail reader, Ableado, Âblage, Iação, Erdrahtung
iCLASS SE / multiCLASS SE
INSTALLATION GUIDE
4
PLT-01579, A.0
R10, RP10, R15, RP15, R30, RP30, R40, RP40, RK40, RPK40
© 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
P1
P2
18 in
(0.46 m)
BEEP
GR
N
GN
D
+VDC
DRAI
N
RE
D
HOLD
GPI0
Hid Iclass Reader
1
GPI0
2
OC/TMP
R
D
ATA
1/CL
K
D
ATA
0/D
ATA
GPI0
3
GPI0
4
BEEP
GRN
GND
+VDC
DRAIN
RED
HOLD
GPI01
GPI02
OC/TMPR
DATA1/CLK
DATA0/DATA
GPI03
GPI04
BEEP
(YEL
)
GRN (ORG
)
GND (BLK
)
+VDC (RED
)
DRAIN (BARE)
RED (BRN)
HOLD (BLU
)
GPIO1 (RED/GRN
)
GPIO2 (T
AN)
OC/TMPR (VIO
)
DA
TA
1/CLK(WHT)
DA
TA
0/D
ATA
(GRN)
GPIO3 (PINK)
GPIO4 (GRA
Y)
ATTENTION
Observe precautions for handling
ELECTROSTATIC SENSITIVE DEVICES
Wiring
C
ableado
C
âblage
f
iação
V
erdrahtung
C
ablaggio
配線
布线
배선
П
ОдКЛючЕнИЕ
ПрОвОдОв
Terminal Reader
Pigtail Reader
2
*
Tamper Output. When activated, output syncs to ground (default).
**
Dependent upon reader configuration.
See HTOG Wiegand and Clock-and-Data configurations for more information.
Pigtail
Terminal Description
Pigtail
Terminal
Description
Yellow
P1-1
Beeper Input
Red / Green
P2-7
GPIO1 (RS232-T / RS485-FDX/HDX-A)
Orange
P1-2
LED Input (GRN)
Tan
P2-6
GPIO2 (RS232-R / RS485-FDX/HDX-B)
Black
P1-3
Ground (RTN)
Violet
P2-5
* Open Collector Output / Tamper
Red
P1-4
+VDC
White
P2-4
** Wiegand Data 1 / Clock
Drain
P1-5
Unused
Green
P2-3
** Wiegand Data 0 / Data
Brown
P1-6
LED Input (RED)
Pink
P2-2
GPIO3 (RS485-FDX-Z)
Blue
P1-7
Hold Input
Gray
P2-1
GPIO4 (RS485-FDX-Y)
*
Salida de sabotaje. Al activarse, la salida se sincroniza con tierra (predeterminado).
**
Depende de la configuración del lector.
Consulte las configuraciones de HTOG Wiegand y Clock-and-Data para obtener más información.
Flexible
Borne
Descripción
Flexible
Borne
Descripción
Amarillo
P1-1
Entrada de bíper
Rojo/ Verde
P2-7
GPIO1 (RS232-T / RS485-FDX/HDX-A)
Naranja
P1-2
Entrada para LED Verde (GRN)
Canela
P2-6
GPIO2 (RS232-R / RS485-FDX/HDX-B)
Negro
P1-3
Conexión a tierra
Violeta
P2-5
*
Salida de colector abierto
Rojo
P1-4
Ryobi ry09056 manual download. +VCC
Blanco
P2-4
**
Datos Wiegand 1 / Reloj
Drenaje
P1-5
Sin uso
Verde
Hid Iclass Se R10 Manual
P2-3
**
Datos Wiegand 0 / Datos
Marrón
P1-6
Entrada para LED Rojo
Rosa
P2-2
GPIO3 (RS485-FDX-Z)
Azul
P1-7
Entrada de retención
Gris
P2-1
GPIO4 (RS485-FDX-Y)
Note: Previous iCLASS readers had reversed
RS-485 wiring ( P2-7 & P2-6 - A & B).
When upgrading to an iCLASS SE reader,
ensure proper connections as defined
below.