Hid Iclass Se R10 User Manual

Iclass se cp1000 encoder user guide. Read online or download PDF. HID iCLASS SE Encoder User Guide User Manual Manuals Directory ManualsDir.com - online owner manuals. View and Download HID ICLASS SE CP1000 quick start manual online. Desktop Encoder. ICLASS SE CP1000 Media Converter pdf manual download.

Page 4: Installation guide 4, Attention, Terminal reader pigtail reader, Ableado, Âblage, Iação, Erdrahtung

Advertising

iCLASS SE / multiCLASS SE

INSTALLATION GUIDE

4

PLT-01579, A.0

R10, RP10, R15, RP15, R30, RP30, R40, RP40, RK40, RPK40

© 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.

P1

P2

18 in

(0.46 m)

BEEP

GR
N

GN
D

+VDC

DRAI

N

RE
D

HOLD

GPI0

Hid Iclass Reader

1

GPI0

2

OC/TMP

R

D

ATA
1/CL

K

D

ATA
0/D
ATA

GPI0

3

GPI0

4

BEEP

GRN

GND

+VDC

DRAIN

RED

HOLD

GPI01

GPI02

OC/TMPR

DATA1/CLK

DATA0/DATA

GPI03

GPI04

BEEP

(YEL

)

GRN (ORG

)

GND (BLK

)

+VDC (RED

)

DRAIN (BARE)

RED (BRN)

HOLD (BLU

)

GPIO1 (RED/GRN

)

GPIO2 (T

AN)

OC/TMPR (VIO

)

DA

TA

1/CLK(WHT)

DA

TA

0/D

ATA
(GRN)

GPIO3 (PINK)

GPIO4 (GRA

Y)

Iclass

ATTENTION

Observe precautions for handling

ELECTROSTATIC SENSITIVE DEVICES

Wiring

C

ableado

C

âblage

f

iação

V

erdrahtung

C

ablaggio

配線

布线
배선
П

ОдКЛючЕнИЕ

ПрОвОдОв

Terminal Reader

Pigtail Reader

2

*

Tamper Output. When activated, output syncs to ground (default).

**

Dependent upon reader configuration.
See HTOG Wiegand and Clock-and-Data configurations for more information.

Pigtail

Terminal Description

Pigtail

Terminal

Description

Yellow

P1-1

Beeper Input

Red / Green

P2-7

GPIO1 (RS232-T / RS485-FDX/HDX-A)

Orange

P1-2

LED Input (GRN)

Tan

P2-6

GPIO2 (RS232-R / RS485-FDX/HDX-B)

Black

P1-3

Ground (RTN)

Violet

P2-5

* Open Collector Output / Tamper

Red

P1-4

+VDC

White

P2-4

** Wiegand Data 1 / Clock

Drain

P1-5

Unused

Green

P2-3

** Wiegand Data 0 / Data

Brown

P1-6

LED Input (RED)

Pink

P2-2

GPIO3 (RS485-FDX-Z)

Blue

P1-7

Hold Input

Gray

P2-1

GPIO4 (RS485-FDX-Y)

*

Salida de sabotaje. Al activarse, la salida se sincroniza con tierra (predeterminado).

**

Depende de la configuración del lector.
Consulte las configuraciones de HTOG Wiegand y Clock-and-Data para obtener más información.

Flexible

Borne

Descripción

Flexible

Borne

Descripción

Amarillo

P1-1

Entrada de bíper

Rojo/ Verde

P2-7

GPIO1 (RS232-T / RS485-FDX/HDX-A)

Naranja

P1-2

Entrada para LED Verde (GRN)

Canela

P2-6

GPIO2 (RS232-R / RS485-FDX/HDX-B)

Negro

P1-3

Conexión a tierra

Violeta

P2-5

*

Salida de colector abierto

Rojo

P1-4

Ryobi ry09056 manual download. +VCC

Blanco

P2-4

**

Datos Wiegand 1 / Reloj

Drenaje

P1-5

Sin uso

Verde

Hid Iclass Se R10 Manual

P2-3

**

Datos Wiegand 0 / Datos

Marrón

P1-6

Entrada para LED Rojo

Rosa

P2-2

GPIO3 (RS485-FDX-Z)

Azul

P1-7

Entrada de retención

Gris

P2-1

GPIO4 (RS485-FDX-Y)

Note: Previous iCLASS readers had reversed

RS-485 wiring ( P2-7 & P2-6 - A & B).

When upgrading to an iCLASS SE reader,

ensure proper connections as defined

below.

Advertising