Ariston E Combi Evo Boiler User Manual

The Ariston evo range is an evolution in boiler technology, making it easy and efficient to reach and maintain the perfect temperature in the home. Our Combi boilers offer excellent domestic hot water flow rates and provide great energy savings thanks to its intelligent technology and ‘AUTO’ function option.

  1. Ariston cannot guarantee the availability of parts for discontinued products and regulations may have changed. Product Any Combi Boilers System Boilers Regular Boilers.
  2. User Manual Dear Customer, Thank you for choosing an ARISTON boiler. We guarantee that your boiler is a reliable and technically sound product. This manual provides detailed instructions and recommendations for the correct use of the appliance. Remember to keep this manual in a safe place for future reference i.e. By the boiler.
  3. Jun 29, 2019  Ariston Clas HE Evo Combi 24 30 38 User Manual Ariston Clas HE Evo Combi 24 30 38 User Manual. June 29, 2019. Back Boiler Manuals. Version 8 Download 0.00 KB File Size 1 File Count June 29, 2019 Create Date August 18, 2019 Last Updated.

Listed below are the common Ariston fault codes as described by the boiler manufacturer along with a possible cause.

Ariston E Combi Evo Boiler User Manual

Ariston Error Codes

Fault CodeBoiler ModelPossible Cause
Central Heating Circuit
101All BoilersOverheat
102E-Combi Evo
E-System Evo
Clas He Evo (Combi and system)
Pressure sensor error
103All BoilersInsufficient circulation
104All BoilersInsufficient circulation
105All BoilersInsufficient circulation
106All BoilersInsufficient circulation
107All BoilersInsufficient circulation
108All Combi BoilersInsufficient water (request filling)
109Clas net one / Clas one Combi
Clas system one
System pressure greater than 3 bar
110All BoilersCentral heating Flow temperature probe circuit open / short circuit
112All BoilersCentral heating return temperature probe circuit open / short circuit
114All BoilersExternal sensor circuit open / short circuit
116All Combi and System BoilersFloor thermostat contact open
118All BoilersHeating delivery probe problem
1p1All BoilersInsufficient circulation indication
1p2All BoilersInsufficient circulation indication
1p3All BoilersInsufficient circulation indication
1p4Clas Net one Combi
Clas one Combi
Clas System one
Insufficient circulation indication
D.H.W Circuit
202Clas HE evo
Clas he evo system
E-combi evo
E-system evo
2 bottom storage temperature probe open/short circuit
204Clas HE evo
Clas he evo system
E-combi evo
E-system evo
Solar collector temperature probe open/short circuit
205E-combi one
E-System one
Clas Net one Combi
Clas one Combi
Domestic hot water in probe open circuit
207Clas HE evo
Clas he evo system
E-combi evo
E-system evo
Solar collector overheating
208Clas HE evo
Clas he evo system
E-combi evo
E-system evo
Collector frost protection temperature
Internal printed circuit board (PCB)
301All BoilersEEPROM error
302All BoilersCommunication error
303All BoilersMain printed circuit board (PCB) error
304All BoilersToo many resets (> 5) in 15 minutes
305All BoilersMain printed circuit board (PCB) error
306All BoilersMain printed circuit board (PCB) error
307All BoilersMain printed circuit board (PCB) error
3P9E-combi one
E-System one
Clas Net one Combi
Clas one Combi
Clas System one
Schedule service
External printed circuit board (PCB)
407Clas HE evo
Clas he evo system
E-combi evo
E-system evo
7 Room sensor circuit open/short circuit
Ignition and Detection
501All BoilersNo flame detected
502All BoilersFlame detected with gas valve closed
504All BoilersFlame lift
5P1All Boilers1st ignition failed
5P2All boilers2nd ignition failed
5P3All BoilersFlame cut-of
Air Inlet / Flue gas outlet
604CLAS HE R
E-Combi Evo
E-System EVO
Clas HE evo Combi
Clas HE evo System
Insufficient fan speed
610All BoilersThermofuse open
612Clas HE Evo Combi
Clas He Evo System
E-Combi Evo
E-system Evo
Clas net one combi
Clas one combi
Clas system one
Fan speed has incorrect measurement
Multi-zone Heating
701E-Combi Evo
E-System EVO
Clas HE evo combi
Clas he evo system
Zone 2 outgoing sensor defective
702E-Combi Evo
E-System EVO
Clas HE evo Combi
Clas HE evo System
Zone 2 return sensor defective
703E-Combi Evo
E-System EVO
Clas HE evo combi
Clas he evo system
Zone 3 outgoing sensor defective
704E-Combi Evo
E-System EVO
Clas HE evo Combi
Clas HE evo System
Zone 3 return sensor defective
705E-Combi Evo
E-System EVO
Clas HE evo combi
Clas he evo system
Hydraulic separation sensor defective
706E-Combi Evo
E-System EVO
Clas HE evo combi
Clas he evo system
Zone 2 overheating
707E-Combi Evo
E-System EVO
Clas HE evo Combi
Clas HE evo System
Zone 3 overheating

Htp Combi Boiler Manual

Clas Net One, Clas One, E-Combi and E-System Error Codes

Fault CodePossible Cause
External printed circuit board (PCB)
411Room sensor circuit open or short circuit zone 1
412Room sensor circuit open or short circuit zone 2
414Room sensor circuit open or short circuit zone 3
Multi-zone Heating
701Send sensor defective (Zone 1)
702Send sensor defective (Zone 2)
703Send sensor defective (Zone 3)
711Return sensor defective (zone 1)
712Return sensor defective (zone 2)
713Return sensor defective (zone 3)
722Overheating in zone 2
723Overheating in zone 3
750All heating zones locked

Hi All,

/best-themes-for-nokia-mobile-download.html. I have an Ariston Clas HE system, it is around 5 years old and it work fine till today. I realized that radiators are cold, went to see what is wrong with the boiler and saw error message 108. Any idea what does it mean, and how to fix it fast without spending a fortune?

Jack

Baxi Combi Boiler Manual

Hi Jack

It is a pressure system fault. You need to do following things on cold boiler: find a braided hose under the boiler, it will have two black or grey knobs. Turn both of them the way they are facing the same way. Look at the pressure needle and fill the system to the value of almost 1.5 bar. Then put the knobs back into its previous position. Restart the boiler.