Find many great new & used options and get the best deals for Allen Bradley SLC 500 1746-ia16 Ser C 115vac 15 Input PLC Module Card at the best online prices at eBay! Free shipping for many products! 2 SLC 500™ Analog Input Module Publication 1746-IN006A-US-P Important User Information Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy. 2 SLC 500™ Analog Input Modules Publication 1746-IN001B-US-P Important User Information Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy. SLC 500™ Analog Input Module 3 For More Information For detailed information on planning and installing your system, see the following publications: Publication Publication Number Industrial Automation Wiring and Grounding Guidelines 1770-4.1 SLC 500™ Analog Input Modules User Manual 1746-6.8 SLC 500™ Modular Hardware Style Operation.
This manual is a reference guide for the 1746–NR4 RTD/Resistance Input Module. The manual:.gives you an overview of system operation.explains the procedures you need to install and wire the module at the customer site.provides ladder programming examples.provides an application example of how this input module can be used to.
Publication 1746-IN006A-US-P
To open downloaded files you need acrobat reader or similar pdf reader program. Fluke 70 ii multimeter user manual. In addition,some files are archived,so you need WinZip or WinRar to open that files. Instead, contact your nearest service center!Note!
Wiring Input Devices to the 1746-NI8
After the analog input module is properly installed in the chassis, follow the wiring
procedure below using Belden 8761 cable.
To wire your 1746-NI8 module follow these steps.
1. At each end of the cable, strip some casing to expose the individual wires.
2. Trim the signal wires to 50 mm (2 inch) lengths. Strip about 5 mm (3/16 inch) of
insulation away to expose the end of the wire.
3. At one end of the cable, twist the drain wire and foil shield together. This end of
the cable is connected to one of the shield terminals on the 1746-NI8 module.
Connect shields for channels 0 through 3 to the upper shield terminal and shields
for channels 4 through 7 to the lower shield terminal.
4. At the other end of the cable, cut the drain wire and foil shield back to the cable.
5. Connect the signal wires and shield drain wire to the 1746-NI8 terminal block or
interposing terminal block.
6. Connect the other end of the cable to the voltage or current transmitter terminals.
7. Repeat steps 1 through 6 for each channel on the module.
!
ATTENTION
Care should be taken to avoid connecting a voltage source to a
current input module. Improper module operation or damage to
the voltage source can occur.
Cable
(Cut foil shield
and drain wire.)
Signal Wire
Signal Wire
Signal Wire
Signal Wire
Foil Shield
Drain Wire
(Twist the drain wire and foil shield together
and connect to earth ground or to the shield
terminal on the 1746-NI8 module.)
00150011001100180012000e001100190012000e00110012@0012001800150017000eJO001100110017'000eVT000eQ000fQE0012001700010001000100120017
00150011001100180012000e001100190012000e00110012@0012001800150017000eJO001100110017'000eVT000eQ000fQE0012001700010001000100120017
00120012001000140010001300110011001700010001000100120011001b00140012001b001200140001'.
00120012001000140010001300110011001700010001000100120011001b00140012001b001200140001'.
4–2
Preliminary Operating Considerations
Publication 1746Ć6.8 - April 1997
The 1746-NI8 analog input module has multiclass interface
capabilities. Class 1 is the standard configuration. The module can
be configured through the user program for Class 3 which enables
user-defined data scaling and monitoring of channel status words.
Configuration
Class 1
Class 3
Compatible SLC
Processors
SLC 500 fixed, SLC 5/01, SLC 5/02,
SLC 5/03, and SLC 5/04
SLC 5/02, SLC 5/03, and SLC 5/04
Compatible
Chassis
local chassis or remote chassis with a
1747ĆASB module
local chassis
Input and
Output Images
output image:
8 channel configuration words
input image:
8 channel data words
output image:
8 channel configuration words and 4 limit ranges
for userĆdefined scaling data format
input image:
8 channel data words and 8 channel status words
Default
Class 1 is the default on powerĆup
Class 3 is programmable by user
The following memory maps show you how the input and output
input image tables are defined for Class 1 and Class 3.
Class 1 Memory Map
Channel 0 Configuration Word
Channel 1 Configuration Word
Channel 2 Configuration Word
Channel 3 Configuration Word
Channel 0 Data Word
Channel 1 Data Word
Channel 2 Data Word
Channel 3 Data Word
Channel 4 Data Word
Channel 5 Data Word
Channel 6 Data Word
Channel 7 Data Word
Output Image
8 Words
Input Image
8 Words
Output Image
Input Image
Output
Scan
Input
Scan
Output Image
Input Image
Slot e
Slot e
SLC 5/0X
Data Files
Analog Input
Module
Image Table
Bit 15
Bit 0
Analog Output Module
Bit 15
Bit 0
Word 0
Word 1
Word 2
Word 3
Word 7
.
.
.
.
.
.
Word 0
Word 1
Word 2
Word 3
Word 4
Word 5
Word 6
Word 7
Address
Address
Types Of Analog Inputs
O:e.0
O:e.1
O:e.2
O:e.3
O:e.7
I:e.0
I:e.1
I:e.2
I:e.3
I:e.4
I:e.5
I:e.6
I:e.7
(Class 1)
Channel 4 Configuration Word
Channel 5 Configuration Word
Channel 6 Configuration Word
Channel 7 Configuration Word
Class 1 and Class 3
Slc 500 Analog Input Module
Interface
Module Addressing