Omron Blood Pressure Monitor Hem-712c User Manual

Advertising
  1. Omron Hem 711acn2 Manual

Instruction Manual Automatic Blood Pressure Monitor with Arm Cuff Model HEM-712C ENGLISH. 3 INTRODUCTION SAVE THESE INSTRUCTIONS. 4 IMPORTANT SAFETY NOTES. 5 BEFORE TAKING A MEASUREMENT. 6 KNOW YOUR UNIT. 7 UNIT DISPLAY IRREGULAR HEARTBEAT SYMBOL. 8 BATTERY INSTALLATION. 9 SETTING THE DATE AND TIME. Omron Healthcare HEM-712C User Manual. How to take a reading, How to use the ac adapter, Care and maintenance. Omron Healthcare Health and hygiene. If during your measurement the monitor. Determines that a higher pressure value is required. Blood pressure.

3

2

page

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Know Your Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Quick Reference Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Battery Installation/Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

How to Apply the Arm Cuff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5

How to Take a Reading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

How to Use the AC Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Error Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Caution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

TwoYear Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

TABLE OF CONTENTS

SYS

TOL

IC m

mH

g

ON

/OF

F

ST

AR

T

DIASTOLIC mmHg

PULSE/min

REA

DY

TO

ME

AS

UR

E

REI

NF

LAT

ING

DE

FLA

TIN

G

REP

LAC

E

BA

TTE

RIE

S

DIG

ITA

L B

LO

OD

PR

ES

SU

RE

M

ON

ITO

R

HE

M-

712

C

Air Jack

Air Plug

Systolic Blood Pressure Display

Diastolic Blood
Pressure/Pulse Display

Arm Cuff

START Button

ON/OFF Button

Introduction

Thank you for purchasing the Omron HEM-712C Automatic Inflation Blood Pressure
Monitor. This completely automatic instrument quickly measures your blood pressure
and pulse rate and displays them on an extra large digital panel.

Your new HEM-712C uses the oscillometric method of blood pressure measurement.
This means the monitor detects your blood's movement through your brachial artery
and converts the movements into a digital reading. An oscillometric monitor does not
need a stethoscope so the monitor is simple to use. The cuff fills with air at the push of
a button and automatically deflates when the measurement is complete. Error indicators
alert you to incorrect procedures and an automatic power-off function conserves the batteries:

Please read this instruction manual thoroughly before using the
Omron HEM-712C Automatic Inflation Blood Pressure Monitor.
For specific information on your own blood pressure,
CONTACT YOUR PHYSICIAN.

KNOW YOUR UNIT

QUICK REFERENCE GUIDE

1. Eating, smoking, and exercising within 30 minutes before taking

a measurement may affect your blood pressure. To take a baseline
blood pressure, rest for at least 5 to 10 minutes before taking a reading.

2. Remove tight-fitting clothing from your upper arm.

The interface of the application is very neat and simple, you will not need any specific technical skills to operate this application. Smith Micro Moho Professional Multilingual Portable 12.2 is a powerful application for creating animations and cartoons through simple drag and drop feature. Portable Smith Micro Moho Pro 12.2 ReviewThere are numerous applications for creating professional animations and cartoons for different purposes, Smith Micro Moho Pro is one of them. /moho-pro-12-user-manual-pdf.html.

3. Sit in a chair with your feet flat on the floor and place your

arm on a table so that the cuff is at the same level as your heart.

4. Put your arm through the cuff loop making sure that the bottom edge

of the cuff is approximately 1/2' above the elbow and that the
Green Marker on the cuff is above brachial artery.

5. Pull the end of the cuff so that the entire cuff is evenly tightened

around your arm and press the hook material firmly against the pile
side of the cuff.

6. Press the ON/OFF button.

7. After the Heart Symbol ( ) appears on the digital panel, press

the Start button, and remain still until the measurement is complete.

8. When measurement is complete, the monitor displays your blood

pressure and pulse rate, and automatically deflates the cuff.

9. Wait 2-3 minutes before taking another blood pressure measurement.

You may require more rest time between readings depending
on your individual physiological characteristics.

Bottom Edge

1/2 Inch

Cuff Tube

Green Marker

Advertising
Popular Brands
Popular manuals
Advertising

Model:

HEM 712C

Display:

Digital LCD

Measurement Range:

Pressure: 0-280mmHg
Pulse: 40-200/minute

Accuracy:

Pressure: ±3 mmHg
or 2% of the reading
Pulse: ±5% of reading

330 shots per charge, and you've got one of the most powerful, exciting COOLPIX cameras yet, the COOLPIX P600. Combine that game-changing zoom power with a CMOS image sensor capable of preserving the fine details of those views, blazing fast autofocus and shooting speeds, a swiveling LCD, manual controls and a battery that lasts up to approx. Moments after you capture an extreme close-up, it can appear on your compatible smartphone or tablet for easy sharing. Nikon coolpix p600 user manual download.

Inflation:

Automatic by
electric pump

Deflation:

Automatic pressure
release valve

Rapid Pressure Release:

Automatic exhaust valve

Pressure Detection:

Capacitance
pressure sensor

Measurement Method:

Oscillometric method

Pulse wave Detection:

Capacitance
pressuresensor

Power Source:

4 “AA” batteries
(not included)
AC Adapter

Battery Life:

Approx. 300 uses
when used once a
day for 2 minutes
(alkaline battery)

Operating Temperature /
Humidity:

50°F to 104°F
(10°C to 40°C)
30-85% RH maximum

Storage Temperature /
Humidity:

-4°F to140°F
(-20°C to 60°C)
10-95% RH maximum

Console Weight w/
batteries:

Approx. 13 oz (380g)

712c

Omron Hem 711acn2 Manual

with batteries

Outer Dimensions:

Approx.
4 1/4' (l) x 5' (w) x 2

1/2'(h)

(107mm x 128mm x 63mm)

Cuff Dimensions:

Approx.

5 1/2'(w) x 18 7/8'(l)

(140mm x 480mm)

Arm Circumference:

9' to 13' (220mm -320mm)

Accessories:

Cuff, Instruction manual

UPC Code

0 73796 07122 6

Except for batteries, NO USER
SERVICEABLE PARTS IN THE
CONSOLE (MAIN UNIT).
NOTE: These specifications,
to improve performance, are
subject to change without notice.

8

ERROR INDICATORS

If you continue to experience difficulty obtaining a reading, call
OMRON HEALTHCARE CUSTOMER SERVICE TOLL FREE 1-800-634-4350.
Please tell the representative you have a Omron Model HEM-712C Automatic Inflation
Blood Pressure Monitor.

Error Symbol

Monitor

Cause

Correction

Cuff under-inflated

.

Carefully read and
repeat in steps listed
under “How To Take
A Reading.”

Batteries have
run down.

Replace all four
“AA”batteries.

Wait 2-3 minutes and
take another measurement.

Repeat steps listed
under “How To
Take A Reading”
but manually inflate
the cuff 40 mmHg
higher than the
previous inflation value.

Movement during

Measurement.

No pulse or blood

pressure reading

due to very weak

artery pulse.

Cuff over-inflated
(more than 300mmHg).

SPECIFICATIONS