Honeywell Scanner Ms9520 User's Manual


Download >> Download Ms9520 programming manual
Read Online >> Read Online Ms9520 programming manual

Mar 15, 2018  4. Scan the Preview Honeywell Scanner Scanner MS9520 User's Manual Online and Download PDF Manuals & Instructions for FREE from Manualagent.com. METROLOGIC INSTRUMENTS INC. MetroSelect® Single-Line. Configuration Guide To properly configure an MS9540 scanner, all programming codes must be scanned using the CodeGate® option.


Honeywell MS9520 User Manual. Your new scanner has been factory configured with a set of default parameters. Since many host systems have unique formats and protocol requirements, Honeywell provides a wide range of configurable features that may be selected using this bar code based configuration tool. Once the configuration is. View and Download Metrologic MS9520 installation and user manual online. MS9500 Voyager Series Single-Line Hand-Held Laser Scanner. MS9520 Barcode Reader pdf manual download. Also for: Ms9540, Voyager ms9500 series, Voyager ms9520-00, Voyager ms9520-9, Voyager ms9520-11, Voyager.

Scan the Recall Default bar code. This will erase all previous settings and return the scanner to its default communication protocol. Keyboard Wedge interface scanners will load keyboard wedge defaults. 02. Scan the enter/exit configuration mode bar code (3 beeps). This will start the scanner configuration mode. 03. GS1 DataBar. Honeywell's MS9520 Voyager® and MS9540 VoyagerCG® scanners with software #14810 and higher can be configured to scan GS1 DataBar type bar codes. ?. 1. 0. 0. 0. 1. 1. Double Border Required – Due to the large spaces commonly found in GS1 DataBar symbologies, Honeywell recommends double. MetroSelect. ®. Single-Line Scanner. Configuration Guide Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are the property of their respective owners. . MS9520 Voyager® and MS9540 VoyagerCG® Series. Activation Range . There are seven bar code lock lengths available. Specific code types can be assigned to a lock length using the Multi-Code configuration method. Example: 1. Scan the enter/exit configuration bar code. 2. Scan the code length lock #1 bar code. 3. Scan the three Code Bytes that represent the code length. 4. Scan the Preview Honeywell Scanner Scanner MS9520 User's Manual Online and Download PDF Manuals & Instructions for FREE from Manualagent.com. METROLOGIC INSTRUMENTS INC. MetroSelect® Single-Line. Configuration Guide To properly configure an MS9540 scanner, all programming codes must be scanned using the CodeGate® option. . Metrologic's MS9520 Voyager® and MS9540 VoyagerCG® laser scanners now have the ability to decode RSS bar Voyager is shipped from the factory programmed with default settings. Refer to the MetroSelect® Programming Guide or MetroSet®2's help files for instructions on how to configure the scanner. MS9520/9540-00 Units Only. All MS9520/9540-00 units leave the factory with Laser Emulation Mode enabled. If you recall defaults Part #. Description. MS9520 or. MS9540. Voyager Bar Code Scanner or. VoyagerCG Bar Code Scanner with CodeGate. 00-02544. MetroSelect Single-Line Configuration Guide*. 00-02410. MS9500 Voyager Series Single-Line Hand Held Laser. Scanner User's Guide*. * Available for download at - www.honeywellaidc.com. View and Download Metrologic MS9520 installation and user manual online. MS9500 Voyager Series Single-Line Hand-Held Laser Scanner. MS9520 Barcode Reader pdf manual download.

Full service restaurant training manual template, Ski guide norge, 2009 beetle car manual, Ltq orbitrap getting started manual windows, Denon 5500 manual.

Honeywell Scanner Ms9520 Manual

MS9520 Voyager

Single-Line Laser Scanner

Honeywell’s MS9520 Voyager® hand-held, single-line laser scanner offers aggressive scanning of all standard 1D bar codes.

The Voyager series of hand-held, single-line bar code scanners have united form with function in becoming the industry benchmark for value and performance.

This sleek scanner features patented automatic infrared activation and decodes all standard 1D bar codes, including GS1 DataBarTM (formerly known as RSS codes).

For presentation scanning, Honeywell offers a stand with automatic in-stand detection technology.

The MS9521 VoyagerHDTM is ideal for applications that require highdensity scanning, delivering quick and accurate scanning of 1D bar codes as small as 3 mil.

Expand scanner functionality by purchasing the MS9524VoyagerPDFTM, which delivers aggressive scanning of all standard 1D bar codes, including PDF.

For more information on the MS9520 Voyager single-line laser scanner, please visit www.honeywell.com/aidc

Features

Automatic Trigger: Use scanner as either a hand-held device or a fixed presentation scanner when mounted in the stand

Honeywell Scanner Ms9520 User

650-nanometer laser: High-visibility laser allows user to place laser line on selected bar code

Flash ROM: Future proof POS system with free firmware updates via MetroSet®2 software and standard PC

Parsing (Data Editing): Format bar code data to meet host system’s specific requirements

Fiat 500 twinair user manual pdf. Fiat 500 Twinair Owners Manual Pdf This fiat punto evo owners manual contains a general description with the Format: PDF - Updated on February 8 FIAT 500 TWIN AIR OWNERS MANUAL. PDF online downloads user manual fiat 500 car from legal resources. Ready to read online or download fiat 500 twinair user manual pdf, free access. Page 2 Dear Customer, Thank you for choosing Fiat and congratulations on your choice of a Fiat We prepared this booklet to enable you to know each detail of your Fiat and use it correctly. Please, read it carefully be- fore driving your car. You will find information, tips and important warnings regarding the driving of your car to help you derive the. View and Download Fiat 2014 500 owner's manual online. 2014 Fiat 500. 2014 Fiat 500 Automobile pdf manual download. Also for: 2014 500c.

Heart strong fitness tracker user manual. Which I think most people don't know!The remote camera function works.I didn't use the ms function yet.I believe ur bluethooth have to be on to receive notifications. Price was good, love the color and style.Works great. I tend to turn it off to save batteries.Like the charging system, no cords. I only turn it on to sync data. Does everything it says that it suppose to.Requires a little patience to setup, and use like every other gadgets!The blood pressure mode etc, u have to press and Wait a little, to see the results.

MS9520 Voyager Series Technical Specifications

Operational

Light Source

Visible Laser Diode 650 nm ± 10 nm

Visual Indicators

Green = ready to scan; Red = good read; Yellow = automatic scanning

Host System Interfaces

USB, RS232, Keyboard Wedge, IBM 46xx (RS485), OCIA, Laser Emulation, Light Pen Wand Emulation

Mechanical

Dimensions (LxWxH)

198 mm x 78 mm x 56 mm (7.8˝ x 3.1˝ x 2.2˝)

Weight

149 g (5.3 oz)

Electrical

Input Voltage

Operating Power (typical)

Standby Power (typical)

DC Transformers

Laser Class

EMC

Environmental

Operating Temperature

Storage Temperature

Humidity

Drop

Environmental Sealing

Light Levels

Scan Performance

Scan Pattern

Scan Speed

Scan Angle

Print Contrast

Pitch, Skew

Decode Capabilities

Warranty

RoHS

2002/95/EC

For more information: www.honeywell.com/aidc

5 VDC + 0.25 V

825 mW (165 mA @ 5 V)

600 mW (120 mA @ 5 V) Class 2: 5.2 VDC @ 1 A

Class 1: IEC60825-1, EN60825-1

FCC Part 15, ICES-003, EN55022 Class B

0°C to 40°C (32°F to 104°F) -40°C to 60°C (-40°F to 140°F)

5% to 95% relative humidity, non-condensing Designed to withstand 1.5 m (5’) drops

Sealed to resist airborne particulate contaminents 4842 Lux (450 foot-candles)

Single scan line

72 scan lines per second Horizontal: 50°

35% minimum reflectance difference

68°, 52°

Reads standard 1D and GS1 DataBar symbologies. PDF417 reading available in MS9524 only. Visit www.honeywell.com/aidc/symbologies for details.

5 year factory warranty

MS9520 / MS9524 Typical Performance*

Narrow Width

Depth of Field

5.2 mil

13 mm - 51 mm (0.5˝ - 2.0˝)

7.5 mil

0 mm - 127 mm (0˝ - 5.0˝)

10.4 mil

0 mm - 165 mm (0˝ - 6.5˝)

13 mil

0 mm - 203 mm (0˝ - 6.5˝)

21 mil

25 mm - 254 mm (0˝ - 6.5˝)

*Resolution: 5 mil (0.127 mm) *Performance may be impacted by bar code quality and environmental conditions

MS9521 Typical Performance*

Narrow Width

Depth of Field

4.0 mil

6 mm - 38 mm (0.3˝ - 1.5˝)

6.8 mil

0 mm - 76 mm (0˝ - 3.0˝)

10.4 mil

0 mm - 108 mm (0˝ - 4.3˝)

13 mil

0 mm - 140 mm (0˝ - 5.5˝)

*Resolution: 3 mil (0.076 mm) *Performance may be impacted by bar code quality and environmental conditions

Honeywell Security & Data Collection

Honeywell Scanning & Mobility 90 Coles Road

Blackwood, NJ 08012 856.228.8100 www.honeywell.com

© 2009 Honeywell International Inc.

MS9520-DS Rev A 01/09

To continue the download you need to go through the captcha: